  • Product Name: Stacked-up Type Heat Exchanger
  • Product Number: 001
  • Views : 2662

Product Features

1.Structure 
The dry type heat exchanger is divided into flat type heat exchanger and stacked-up type heat exchanger by structure type. 
The users can select structure types according to the fields and installation requirements. 

The flat type heat exchanger ensures structural strength and features simple appearance 

due to the structure type of tube plate and support. 

Both the flat type heat exchanger and stacked-up type heat exchanger give full consideration to 

the convenience of the connecting tube of the compressor and optimize tube connection 

so that the complete machine looks as simple as heat exchangers. 

The design of the liquid distribution cavity of the evaporator is optimized as if 

a liquid distributor is installed in the liquid distribution system,

 thereby realizing the most reasonable distribution of refrigerant liquid. 

2.Safety Performance and Manufacture 
The design of structural strength and heat and mass transfer is optimized in strict accordance with the national standard,

 thereby ensuring performance,increasing the utilization rate of materials and meeting the national requirements 

on energy conservation and consumption reduction. 

By virtue of advanced processing equipment including CAX and CNC center as well as 50 years of experience 

in manufacturing of refrigerating containers, product manufacture can fully conform to the design concept. 

The great advantage is that refrigerant charge is 1/3 of full liquid type. 

The disadvantage is that COP is not higher than that of full liquid type under the same working conditions. 

  Operating Conditions

Water Quality

(1)It can be widely applied to river water, lake water and underground water.

(2)It can be used for corrosive media such as sewage, seawater, etc. 

Working Condition

It can be widely applied to air conditioning, water source heat pump and ground source heat pump.  

Applications 

The central air conditioner equipped with this series of heat exchanger is widely used in 

various industries such as aerospace, ships, high-grade entertainment venues,

 large shopping centers, supermarket, etc. 

 Maintenance

The maintenance measures of the heat exchanger on first use or starting using in a new season

1.

When winter arrives in north China, please drain the circulating water from

 the evaporator and condenser through the drain valve 

when the machine is not used for heat supply so as to avoid frozen crack of

 the heat exchange tube due to the residual water in the container. 

2.

Please open the drain valve of the system and heat exchanger and drain the water 

from the system before starting the compressor. 

Please fill the heat exchanger with water slowly so as to avoid the situations that may seriously impact unit operation 

such as vibration crack of the heat exchange tube due to resonance caused by 

large impact to the heat exchange tube and evaporator because of large flow rate when starting the machine, 

inner leakage of the heat exchanger, water flowing in the compressor, etc. 

 

3.

The chemical reagent with certain concentration is recommended in case of severe fouling of the heat exchanger. 

Please drain the reagent solution from the circulating pump after it is circulated by 

the circulating pump for 24 hours and ensure good heat exchange efficiency of the heat exchanger.